conform Regulamentului (CE) Nr. 1907/2006 (REACH) și Regulamentului (UE) Nr 2020/878
Item number/ Trade name: 16413-10-6 Print date: 06/18/2024
Version/Issue date: 2 / 06/02/2023 Page: 1 of 8
Colour for candles
Item number/ Trade name 16413-10-6
General use Coloration of hydrocarbons, waxes, oils and fats
Company/undertaking identification
Name bekro chemie GmbH & Co. KG
Street/POB-No.: 1 Industriestrasse 104
City D-66802 Ueberherrn
Phone # +49 6836 9198 0
Telefax # +49 6836 9198 10
E-mail info@bekro.de
Name bekro chemie GmbH & Co. KG (Mo - Thu 8.00 - 16.30, Fr 8.00 - 14.30)
Phone # +49 6836 9198 0
Clasificare conform regulamentului CE 1272/2008 (CLP)
Amestecul este clasificat ca nepericulos conform regulamentului (CE) Nr 1272/2008 [CLP].
Signal word ---
Nature of Hazard ---
Hazard statements no hazard labelling required
Safety precautions ---
Hazard components for labelling ---
Special provisions concerning the labelling of certain mixtures ---
---
Mixture of waxes, colouring agents and additives
Hazardous ingredients
---
General information If you feel unwell, seek medical advice.
In case of inhalation Move victim to fresh air. Seek medical aid in case of troubles.
In case of skin contact Thoroughly wash skin with soap and water.
After eye contact Immediately flush eyes with plenty of flowing water for 10 to 15 minutes holding eyelids apart. Seek medical attention if irritation persists.
After swallowing Do NOT induce vomiting. Rinse mouth immediately and drink plenty of water. Seek medical treatment in case of troubles.
Symptoms No data available
Information to physician No data available
Suitable extinguishing media Carbon dioxide , water spray jet , extinguishing powder , foam.
Extinguishing media which must not be used for safety reasons Full water jet
Possible combustion products Nitrogen oxides (NOx), carbon monoxide and carbon dioxide
Special protective equipment for firefighters Wear self-contained breathing apparatus.
Additional information Do not allow water used to extinguish fire to enter drains, ground or waterways. Do not allow fire water to penetrate into surface or ground water. You have to dispose of contaminated extinguishing water according to the regulations of the authorities.
Avoid dust formation. Do not breathe dust. With the formation of dust, use a dust mask. Keep away from sources of ignition - No smoking. Avoid contact with skin, eyes, and clothing.
Do not allow to enter into ground-water, surface water or drains. Discharge into the environment must be avoided.
Take up spilled product with dustpan and brush. Avoid causing any dust. Industrial vacuum cleaner recommended to avoid causing dust. Clean soiled areas with a conventional household cleaner.
Personal protection equipment: see section 8, Disposal: see section 13
Advices on safe handling Avoid contact with eyes and skin. When using do not eat, drink, smoke, sniff. Make sure there is sufficient air exchange and / or that working rooms are air suctioned. Avoid dust formation.
Requirements for storerooms and containers Keep away from sources of ignition and heat. Store in a cool dry place. Store in a well-ventilated place. Keep container tightly closed. Protect from direct sunlight.
Storage class 11
General use Coloration of hydrocarbons, waxes, oils and fats
---
Respiratory protection With correct and proper use, and under normal conditions, breathing protection is not required. Provide good ventilation and/or an exhaust system in the work area. Wear a dust mask, in case of excessive dust.
Hand protection Wear suitable gloves.- according to DIN-/EN-Norms EN 420, EN 388 and EN 374 Part 1,3
Eye protection Goggles according to EN 166.
Body protection Wear suitable protective clothing and shoes.
General protection and hygiene measures Keep away from food and drinks. When using do not eat, drink or smoke. Wash hands before breaks and after work. Wash contaminated clothing prior to re-use.
| Proprietate | min | max | Observații |
|---|---|---|---|
| Form | solid | ||
| Colour | brown | ||
| Odour | characteristic | ||
| Melting point/freezing point | > 60 °C | --- | |
| Initial boiling point and boiling range | > 130 °C | --- | |
| Flammability | --- | ||
| Explosion limits | --- | --- | |
| Flash point/flash point range | > 150 °C | --- | |
| Ignition temperature | --- | --- | |
| PH | --- | --- | --- |
| Viscosity | 0 mPa.s | 0 mPa.s | --- |
| Solubility | --- | --- | --- |
| Partition coefficient: n-octanol/water | --- | --- | |
| Vapour pressure | --- | --- | |
| Density and/or relative density | --- | --- | |
| Relative vapour density | --- | --- | |
| Bulk density | --- | --- | |
| Flow time 4mm (DIN) | --- | --- | |
| Water solubility | Product is difficult to dissolve in water. | ||
---
Non-reactive
Product is stable under normal storage conditions.
No data available
Avoid dust formation. Avoid dust deposits. Keep away from sources of ignition - No smoking. Take precautionary measures against static discharges.
strong acids and bases, strong oxidizing agents
In case of fire may be liberated: Nitrogen oxides (NOx), carbon monoxide and carbon dioxide
General remarks
No toxicological tests were conducted with the mixture.
Endocrine disrupting properties No data available
Further details No data available
Aquatic toxicity No data available
Evaluation text No data available
Degree of elimination No data available
Analytical method No data available
No data available
No data available
No data available
No data available
The ecotoxicological properties of this mixture are determined by the ecotoxicological properties of the single components (see section 3).
Product
Recommendation Dispose of waste according to applicable legislation. Discharge into the environment must be avoided.
Package
Recommendation Dispose of waste according to applicable legislation. Non-contaminated packages may be recycled. Handle contaminated packages in the same way as the substance itself.
ADR, IATA, IMDG not regulated
Product designation: ADR/RID No dangerous good in sense of these transport regulations.
Proper shipping name: IATA-DGR ---
Proper shipping name: IMDG ---
Class ADR/RID ---
Classification code ---
ADR/RID
Class IATA-DGR ---
Subrisk IATA-DGR ---
Class IMDG ---
Subrisk IMDG ---
ADR, IATA, IMDG No packaging for dangerous goods required
Marine Pollutant - IMDG ---
EmS ---
Stowage and segregation ---
---
---
EQ ---
Limited quantities ---
Special Provisions ---
Tunnel restriction ---
Transport category ---
Kemmler-number ---
No dangerous good in sense of these transport regulations.
National regulations
Europe ---
Germany
Storage class 11
Water Hazard Class 1
Incident regulation ---
Information on working limitations No special measures are required.
Chemical Safety Assessment No substance safety evaluation was conducted with the mixture/ substance.
Hazard statements (CLP) no hazard labelling required
Reason of change General revision
| Abreviere | Semnificație |
|---|---|
| --- | no data, not determined or not applicable |
| REACH | Registration, Evaluation, Authorisation and Restriction of Chemicals (Regulation (EC) No. 1907/2006) |
| OECD | Organisation for Economic Co-operation and Development |
| LD50 | Median lethal dose |
| LC50 | Median lethal concentration |
| EC50 | Median effective dose |
| IC50 | Median inhibitory concentration |
| VCI | Verband der chemischen Industrie |
| CAS | Chemical Abstract Service |
| EINECS | European Inventory of Existing Commercial Chemical Substances |
| ELINCS | European List of Notified Chemical Substances |
| NLP | No Longer Polymers |
| CLP | Regulation (EC) No 1272/2008 on Classification, Labelling and Packaging |
| EG | European Union |
| WGK | water hazard class (according to AwSV, Appendix 1 (5.2)) |
| AGW | Occupational Exposure Limit |
| ADR | Accord Européen relatif au transport international des marchandises dangereuses par route (European Agreement concerning the International Carriage of Dangerous Goods by Road) |
| RID | Règlement concernant le transport international ferroviaire des machandises dangereuses (Regulation on the international carriage of dangerous goods by rail) |
| IATA | International Air Transport Association |
| IMDG | International Martime Dangerous Goods |
| MARPOL | International Convention for the Prevention of Pollution From Ships (MARine POLlution) |
| EmS | Emergency Schedules |
| PBT | persistent, bioaccumulative and toxic |
| vPvB | very persistent and very bioaccumulative |
Informacje podane w tym formularzu zestawiono wedêług najlepszej wiedzy i odzwierciedlają one wyniki dotychczasowych badań naukowych. Nie gwarantują one jednak dotrzymania definowalnych w postaci zapisów prawnych właściwości.